CURRENT SENSOR TRANSFORMER

PTC-02 SERIES
CURRENT SENSOR TRANSFORMERS

FEATURES AND CHARACTERISTICS

  • Maximum ratings specified with rated secondary terminating resistance and one turn primary.
  • Amp-micro second (AmSec.) rating of primary equals volt-microsecond (VmSec.) rating of secondary when secondary is terminated in rated resistance. (Amp-microseconds is equal to the product of a square pulse of current in amps times the current pulse width in micro seconds).
  • Maximum operating temperature: 105 degree C.
  • When terminated with rated terminating resistance the inductor scale factor is V out = 1 volt per amp for center tapped units terminating resistance for each half of winding is listed value divided by 2.
  • Secondary is fully isolated to > 2500 V.
  • Useful operation to > 100 KHZ.
  • Not suitable for measurement of DC current. Current waveform must be free of any DC component.
PTC-02 SERIES     
Part Number Secondary Turns Secondary Incductance MHY (min.) Secondary DCR OHMS (max.) Secondary Rated Terminating Resistance OHMS (Nominal) 1 Turn Primary Peak Sense Current (Amps) Secondary Inductance Test Voltage 10 KHz Primary Unipolar Amp m Sec. Rating (max.) Primary Bipolar Amp m Sec. Rating (max.) Schematic Figure
PTC-02-105 25 + 25 5.0 0.7 25/side 20.0 0.5 150.0 300.0 B
PTC-02-110 50 + 50 20.0 1.4 50/side 20.0 1.0 300.0 600.0 B
PTC-02-115 100 + 100 80.0 4.5 100/side 20.0 2.0 600.0 1200.0 B
PTC-02-120 150 +150 180.0 11.0 150/side 20.0 3.0 900.0 1800.0 B