FEATURES AND CHARACTERISTICS
- Maximum ratings specified with rated secondary terminating resistance and one turn primary.
- Amp-micro second (AmSec.) rating of primary equals volt-microsecond (VmSec.) rating of secondary when secondary is terminated in rated resistance. (Amp-microseconds is equal to the product of a square pulse of current in amps times the current pulse width in micro seconds).
- Maximum operating temperature: 105 degree C.
- When terminated with rated terminating resistance the inductor scale factor is V out = 1 volt per amp for center tapped units terminating resistance for each half of winding is listed value divided by 2.
- Secondary is fully isolated to > 2500 V.
- Useful operation to > 100 KHZ.
- Not suitable for measurement of DC current. Current waveform must be free of any DC component.
| PTC-01 SERIES | ||||||||||||||||||||||||
| Part Number | Secondary Turns | Secondary Incductance MHY (min.) | Secondary DCR OHMS (max.) | Secondary Rated Terminating Resistance OHMS (Nominal) | 1 Turn Primary Peak Sense Current (Amps) | Secondary Inductance Test Voltage 10 KHz | Primary Unipolar Amp m Sec. Rating (max.) | Primary Bipolar Amp m Sec. Rating (max.) | Schematic Figure | PTC-01-105 | 50.0 | 5.0 | 0.7 | 50.0 | 20.0 | 0.5 | 150.0 | 300.0 | A | |||||
| PTC-01-110 | 100.0 | 20.0 | 1.4 | 100.0 | 20.0 | 1.0 | 300.0 | 600.0 | A | |||||||||||||||
| PTC-01-115 | 200.0 | 80.0 | 4.5 | 200.0 | 20.0 | 2.0 | 600.0 | 1200.0 | A | |||||||||||||||
| PTC-01-120 | 300.0 | 180.0 | 11.0 | 300.0 | 20.0 | 3.0 | 900.0 | 1800.0 | A | |||||||||||||||